{"product_id":"avnan-dual-motor-12-amp-240v-circuit-board-for-md-central-vacuum-236m","title":"Avnan Dual Motor 12 Amp 240V Circuit Board for MD Central Vacuum – Part# 236M","description":"\u003ch2\u003eQuick Summary\u003c\/h2\u003e\n\u003cp\u003eThis replacement circuit board control module is designed for 240 volt, dual motor central vacuum units under 8 amp. It includes a relay, transformer, mini breaker, ground, and two pairs of low voltage leads.\u003c\/p\u003e\n\u003cp\u003eAvailable from \u003cstrong\u003eAce Vacuums\u003c\/strong\u003e, with help matching parts to your MD central vacuum system at our Fairfax and Leesburg, VA showrooms.\u003c\/p\u003e\n\u003ch3\u003eQuick Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor 240 volt dual motor units under 8 amp\u003c\/li\u003e\n\u003cli\u003eIncludes relay, transformer, and mini breaker\u003c\/li\u003e\n\u003cli\u003eIncludes ground and two pairs of low voltage leads\u003c\/li\u003e\n\u003cli\u003eBoard height is 2.5 inches to top of reset button\u003c\/li\u003e\n\u003cli\u003eMounts through holes from inside the vacuum\u003c\/li\u003e\n\u003cli\u003eExternal mounting nuts are included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThis control module circuit board is used in select MD central vacuum power units and is intended for 240 volt, dual motor units under 8 amp. It includes the main onboard components noted in the product details, including a relay, transformer, mini breaker, ground, and two pairs of low voltage leads.\u003c\/p\u003e\n\u003cp\u003eThe board mounts through holes from within the vacuum. The reset button and threaded low voltage stems, along with the included nuts, hold the board in place.\u003c\/p\u003e\n\u003cp\u003eBecause this board does not work on all vacuums, it is important to confirm fit before ordering. Quarter inch female spade terminals are not included.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e240V dual motor application:\u003c\/strong\u003e Designed for 240 volt, dual motor central vacuum units under 8 amp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete control module layout:\u003c\/strong\u003e Board includes a relay, transformer, mini breaker, ground, and two pairs of low voltage leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal mounting design:\u003c\/strong\u003e This board mounts through holes from within the vacuum body.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset button retention:\u003c\/strong\u003e The reset button and low voltage stems help secure the board in place with the included nuts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded mounting hardware:\u003c\/strong\u003e External mounting nuts are included with the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference dimensions provided:\u003c\/strong\u003e The product details include spacing and height measurements to help with identification and installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eMD Compatibility\u003c\/h2\u003e\n\u003cp\u003eThis part is listed as the match for these MD central vacuum power units:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMD B2 (240V)\u003c\/li\u003e\n\u003cli\u003eMD E2 (240V)\u003c\/li\u003e\n\u003cli\u003eMD M575H2 (240V)\u003c\/li\u003e\n\u003cli\u003eMD M715H2 (240V)\u003c\/li\u003e\n\u003cli\u003eMD QE2 (240V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the model number on your power unit label before ordering. Our team can confirm the match if you are unsure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAvnan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e236M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Configuration\u003c\/td\u003e\n\u003ctd\u003eDual motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp Application\u003c\/td\u003e\n\u003ctd\u003eUnder 8 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Height\u003c\/td\u003e\n\u003ctd\u003e2.5 in. from metal frame to top of reset button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Edge Dimension\u003c\/td\u003e\n\u003ctd\u003e2.75 in. from outer edges of reset button and low voltage connection stem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter-to-Center Spacing\u003c\/td\u003e\n\u003ctd\u003e2.125 in. (2-1\/8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eRelay, transformer, mini breaker, ground, two pairs of low voltage leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eThrough holes from within the vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Included\u003c\/td\u003e\n\u003ctd\u003eExternal mounting nuts included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits MD Models\u003c\/td\u003e\n\u003ctd\u003eMD B2 (240V), MD E2 (240V), MD M575H2 (240V), MD M715H2 (240V), MD QE2 (240V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility Note\u003c\/td\u003e\n\u003ctd\u003eIncludes: AirMaster, Modern Day, SilentMaster, Flo-Master and Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthorized Dealer\u003c\/td\u003e\n\u003ctd\u003eAce Vacuums\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eBest For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReplacing a failed control board in select MD central vacuum units\u003c\/li\u003e\n\u003cli\u003e240V dual motor systems under 8 amp\u003c\/li\u003e\n\u003cli\u003eMatching the listed board dimensions and mounting style\u003c\/li\u003e\n\u003cli\u003eMD B2, E2, M575H2, M715H2, and QE2 240V units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eNot Ideal For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNot for all central vacuum models\u003c\/li\u003e\n\u003cli\u003eNot suitable if your vacuum does not match the listed mounting layout\u003c\/li\u003e\n\u003cli\u003eQuarter inch female spade terminals are not included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy from Ace Vacuums\u003c\/h2\u003e\n\u003cp\u003eWhen you purchase from \u003cstrong\u003eAce Vacuums\u003c\/strong\u003e, you receive:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCentral vacuum parts matched to your MD system\u003c\/li\u003e\n\u003cli\u003eHelp choosing the right hose, tools and inlet parts\u003c\/li\u003e\n\u003cli\u003eKnowledgeable support before and after the sale\u003c\/li\u003e\n\u003cli\u003eShipping or pickup at our Fairfax and Leesburg showrooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailable Online \u0026amp; In-Store\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAvnan Dual Motor 12 Amp 240V Circuit Board for MD Central Vacuum\u003c\/strong\u003e is available online and in-store through \u003cstrong\u003eAce Vacuums\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eVisit Our Showrooms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFairfax, VA:\u003c\/strong\u003e 11110 Main St, Fairfax, VA 22030\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeesburg, VA:\u003c\/strong\u003e 300 Fort Evans Rd NE, Leesburg, VA 20176\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCall 703-997-9292 (ext. 1 Fairfax, ext. 2 Leesburg).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eFAQs\u003c\/h5\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eWhat does this circuit board include?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eIt includes a relay, transformer, mini breaker, ground, and two pairs of low voltage leads.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eWhat type of vacuum is this board for?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eIt is described as a control module for 240 volt, dual motor, under 8 amp central vacuum units.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eWhich MD central vacuum models is this part listed for?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eIt is listed for MD B2 (240V), MD E2 (240V), MD M575H2 (240V), MD M715H2 (240V), and MD QE2 (240V).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eHow is this board mounted?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eMount the board through holes from within the vacuum. The reset button and the threaded low voltage stems, along with the included nuts, hold the board in place.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eAre mounting nuts included?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eYes. The external mounting nuts are included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eAre spade terminals included with the board?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eNo. Quarter inch female spade terminals are not included.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eWhat dimensions are provided for identification?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eThe board is 2.5 inches high from the metal frame to the top of the reset button. The outer edge dimension between the reset button and low voltage connection stem is 2.75 inches, and those two round structures are 2.125 inches center to center.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"ace-faq\" style=\"border-bottom: 1px solid #dddddd; padding: 14px 0;\" name=\"ace-faq-accordion\"\u003e\u003csummary style=\"cursor: pointer; font-weight: 600; font-size: 16px; line-height: 1.5; display: list-item;\"\u003eWill this fit my MD central vacuum?\u003c\/summary\u003e\u003cdiv style=\"padding: 12px 0 0;\"\u003e\u003cp\u003eNot always. This board does not work on all vacuums, so confirm your MD central vacuum model and compare the listed dimensions and mounting points before ordering.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e","brand":"Avnan","offers":[{"title":"Default Title","offer_id":53406068441269,"sku":"236M","price":78.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0575\/6751\/0709\/files\/236M_100_56790d65-c81e-4c57-8f3e-61e81ce70787.jpg?v=1790801077","url":"https:\/\/acevacuums.com\/products\/avnan-dual-motor-12-amp-240v-circuit-board-for-md-central-vacuum-236m","provider":"Ace Vacuums","version":"1.0","type":"link"}